Our self regulating and power limiting trace heating systems for frost protection and temperature maintenance (up to 235°C / depending on cable type) in hazardous areas.
All types of BTV, QTVR, XTV, KTV and VPL familys of self-regulating, parallel circuit heating cables by Raychem.
All types of KT, HKT familys of self-regulating heating cables by Klöpper-Therm.
Our self-regulating product range for industrial (can be used in hazardous areas) frost protection and temperature maintenance up to 65°C / Maximum maintain or continuous exposure temperature (power on) +65°C and maximum intermittent exposure temperature (power off) +85°C (maximum cumulative exposure 1000 hours):
Raychem
3BTV2-CT 9 W/m @ +10°C
5BTV2-CT 16 W/m @ +10°C
8BTV2-CT 25 W/m @ +10°C
10BTV2-CT 30 W/m @ +10°C
Temperature classification: T6
Supply voltage: 220 - 277 VAC
Maximum continuous exposure temperature (power on): 65°C
maximum intermittent exposure temperature (power off): 85°C (maximum cumulative exposure 1000 hours)
Minimum installation temperature: -60°C
Minimum bend radius: 13 mm @ 20°C, 35 mm @ -60°C
Our self-regulating product range for industrial (can be used in hazardous areas) frost protection and temperature maintenance up to 65°C / Maximum maintain or continuous exposure temperature (power on/off) +110°C:
Raychem
10QTVR2-CT 38 W/m @ +10°C
15QTVR2-CT 51 W/m @ +10°C
20QTVR2-CT 63 W/m @ +10°C
Temperature classification: T4
Supply voltage: 220 - 277 VAC
Maximum continuous exposure temperature (power on/off): 110°C
Minimum installation temperature: -60°C
Minimum bend radius: 13 mm @ 20°C-nál, 35 mm @ -60°C)
Our self-regulating product range for industrial (can be used in hazardous areas) frost protection and temperature maintenance up to 150°C / Maximum maintain or continuous exposure temperature (power on) and maximum intermittent exposure temperature (power off) +250°C (maximum cumulative exposure 2000 hours):
Raychem
3XTVR2-CT 9 W/m +10°C
5XTVR2-CT 16 W/m +10°C
8XTVR2-CT 25 W/m +10°C
10XTVR2-CT 32 W/m +10°C
12XTVR2-CT 38 W/m +10°C
15XTVR2-CT 48 W/m +10°C
20XTVR2-CT 64 W/m +10°C
Supply voltage: 190 - 277 VAC
Maximum continuous exposure temperature (power on): 150°C
maximum intermittent exposure temperature (power off): 250°C (maximum cumulative exposure 1000 hours)
Minimum installation temperature: -60°C
Minimum bend radius: 13 mm @ 10°C, 51 mm @ -60°C
Our self-regulating product range for industrial (can be used in hazardous areas) frost protection and temperature maintenance up to 205°C / Maximum maintain or continuous exposure temperature (power on) +205°C and maximum intermittent exposure temperature (power on/off) +260°C (maximum cumulative exposure 2000 hours):
Raychem
3HTV2-CT 9 W/m +10°C
5HTV2-CT 16 W/m +10°C
8HTV2-CT 25 W/m +10°C
10HTV2-CT 32 W/m +10°C
12HTV2-CT 38 W/m +10°C
15HTV2-CT 48 W/m +10°C
20HTV2-CT 64 W/m +10°C
28HTV2-CT 88 W/m +10°C
Supply voltage: 190 - 277 VAC
Maximum continuous exposure temperature (power on): 205°C
maximum intermittent exposure temperature (power on/off): 260°C (maximum cumulative exposure 1000 hours)
Minimum installation temperature: -60°C
Minimum bend radius: 13 mm @ 10°C, 25 mm @ -60°C
Our power limiting product range for industrial (can be used in hazardous areas) frost protection and temperature maintenance up to 150-230°C (*) / Maximum maintain or continuous exposure temperature (power on) +150-230°C (*) and maximum intermittent exposure temperature (power off) +260°C (maximum cumulative exposure 1000 hours):
* depending on cable type
Raychem – 5VPL2-CT (* 230°C), 10VPL2-CT (* 210°C), 15VPL2-CT (* 180°C), 20VPL2-CT (* 150°C)
5VPL2-CT 15 W/m @ +10°C
10VPL2-CT 30 W/m @ +10°C
15VPL2-CT 45 W/m @ +10°C
20VPL2-CT 61 W/m @ +10°C
Temperature classification: T2-T4 (Use TraceCalc design software or contact for assistance)
Supply voltage: 220 - 277 VAC
Maximum continuous exposure temperature (power on): 230°C (5VPL2), 210°C (10VPL2), 180°C (15VPL2), 150°C (20VPL2)
maximum intermittent exposure temperature (power off): 260°C
Minimum installation temperature: -60°C
Minimum bend radius: 20 mm @ 20°C, 20 mm @ -60°C